Browse all practice questions for the ARMRIT Registry Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ARMRIT Registry Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Why can ferrous implants pose a danger in magnetic fields?
  • Among the types of magnets used in MRI, which one yields the highest magnetic field strength?
  • The physical gradient that encodes in the anterior-posterior direction is referred to as?
  • True or False: Before entering Zone 2, patients need to be screened.
  • What is a main characteristic that distinguishes Inversion Recovery from Spin Echo?
  • What does TR stand for in a spin echo pulse sequence?
  • When TR is shorter than a tissue's T2 decay time, the remaining transverse magnetization is known as:
  • As receive bandwidth increases, how is scan time affected?
  • What happens to SNR as the Field of View (FOV) increases?
  • What does the 90 degree RF pulse do in a spin echo sequence?
  • What is the role of phase and frequency encoding gradients?
  • What describes the slope of the gradient derived from both rise time and amplitude?
  • Increasing slice thickness results in a decrease in which of the following?
  • Which pulse is used for refocusing in a spin echo pulse sequence?
  • In a pulse sequence diagram, what function does Gy serve?
  • Immediately after the 90 degree RF pulse in a spin echo pulse sequence, the spins are described as?
  • What mathematical process is used in MRI image reconstruction?
  • What characteristic of GBCA's identifies them as paramagnetic?
  • What does magnetic susceptibility refer to in terms of tissue?
  • Radiofrequency leaks into the magnet room can result in an artifact often referred to as?
  • Why are GBCA's classified as T1 shortening agents?
  • What does higher signal-to-noise ratio generally indicate in MRI tissue imaging?
  • What does the term 'echo train length' refer to in MRI?
  • What changes from one TR period to the next in a spin echo pulse sequence?
  • What does the term Specific Absorption Rate (SAR) refer to?
  • Which of the following are the four main parts of any pulse sequence?
  • In MRI, a rotating proton's type of inertia is referred to as what?
  • What is the term for the medium used to make a conductor superconductive?
  • Which computer component is responsible for the mathematical reconstruction of MRI images?
  • How many gradient coils are present in a standard MRI system?
  • In the case of a sudden release of gaseous helium into the magnet room, what should be the very first action taken by the tech?
  • In a spin echo pulse sequence, what does FID stand for?
  • What does the amplitude of a gradient represent in an MRI context?
  • FLAIR imaging is particularly useful in highlighting which types of pathologies?
  • What type of magnet requires special cooling to maintain its magnetic field?
  • How does scan time change as slice thickness increases?
  • Radio frequency burns typically occur from which of the following?
  • When can MR image artifacts occur?
  • What is the default frequency encoding direction for an axial image of the brain?
  • In a spin echo sequence, if 120 phase encoding steps are selected, how many times is the TR repeated?
  • At what temperature does helium liquify, which is equivalent to 4 degrees Kelvin?
  • The effect of gradients on spins primarily involves which aspect?
  • How does increasing TR affect the signal-to-noise ratio (SNR)?
  • What is the effectiveness of gradient echoes in correcting dephasing caused by inhomogeneities compared to 180-degree radio frequency echoes?
  • How do the adverse reactions of GBCA's compare to those of iodine based contrast agents?
  • Which type of MRI magnet is most commonly used in "open" designs?
  • What does echo spacing represent in MRI imaging?
  • Zone III in an MRI facility is considered which area?
  • What effect does an increase in TR have on the signal to noise ratio?
  • If the echo train length is 8 and the number of phase encoding steps selected is 256, how many times is the TR repeated?
  • Chemical shift artifacts occur in which direction?
  • In what unit is SAR measured?
  • What happens to the processional frequency when a gradient magnetic field is applied?
  • What type of artifact can be reduced by breath-holding techniques during imaging?
  • What happens to spatial resolution as slice thickness increases?
  • Which time interval refers to the duration from a gradient's minimum to maximum field difference?
  • Who is credited with the concept and development of MRI gradient fields?
  • A vector is best described as a graphic illustration that shows what two properties?
  • What impact does increasing TE have on scan time?
  • What does the Larmor equation represent in terms of frequency?
  • As the Phase Matrix increases, which of the following decreases?
  • Which is the heaviest type of magnet used in MRI applications?
  • Which of the following is not a factor causing MR image artifacts?
  • What is the unit of measurement for slew rate?
  • What is the source of magnetism in materials?
  • What effect does increasing TR have on spatial resolution?
  • What effect do all metal implants have on the magnetic field?
  • In an MRI environment, which direction does the Z axis point when looking at the front of the MR system?
  • Who holds the ultimate responsibility for safety in the magnet room?
  • As FOV increases, what happens to SNR?
  • In which type of sequence are gradient echoes typically used?
  • True or False: A cardiac pacemaker is always a contraindication for an MRI.
  • Which imaging technique utilizes gradient moment nulling?
  • How often are MRI related accidents reported?
  • Which group of patients needs to be monitored closely during an MRI to prevent injuries?
  • What phenomenon occurs when there is a great variance of T2 decay in the echo train length (ETL)?
  • The force exerted by a magnet on an object largely depends on which factors?
  • Which of the following is NOT a type of radio frequency burn?
  • No one should enter Zone _______ until they are screened.
  • Which lines in k-space contain the majority of spatial resolution information?
  • In a spin echo pulse sequence, what is the first gradient used?
  • Which parameter is used to reduce flow artifacts involving blood or CSF?
  • What does Gx indicate in a pulse sequence diagram?
  • In a spin echo pulse sequence, which gradient encodes the slice?
  • What distinguishes ionic agents from non-ionic agents in contrast media?
  • What is the main purpose of engineering a non-toxic chemical to attach to the Gd ion?
  • What is one effective method for reducing metal artifacts?
  • What does it mean for a tissue to be "saturated" in MRI terms?
  • How many phase encoding steps are collected every TR period in a spin echo pulse sequence?
  • How does the calculation for scan time in a fast/turbo spin echo compare to a spin echo?
  • What is the most common artifact encountered in MR imaging?
  • How does the effectiveness of 180-degree refocusing pulses in correcting dephasing compare to gradient echoes?
  • How can hardware failures contribute to MR image artifacts?
  • What is an example of an action that may cause a physiological image artifact?
  • What impact does an increase in phase matrix have on SNR?
  • On a T1 weighted image, why does CSF appear dark?
  • In MR imaging, what could lead to artifacts related to the patient?
  • A quench can either be _______________ or _______________?
  • In a pulse sequence diagram, Gz is used to represent?
  • What is the name of the transmitting antenna surrounding the patient in all MRI systems?
  • In a superconductive magnet, what happens to the electrical current flowing through it?
  • In a T2 weighted FLAIR sequence, what is suppressed to highlight long T2 pathologies?
  • In a spin echo sequence, the first RF pulse is known as?
  • What device is used to hold liquid helium in superconductive magnets?
  • Which artifact is characterized by intensity variations due to a lack of contrast agent?
  • What are examples of fat suppression techniques in MRI?
  • If TE is increased in a spin echo pulse sequence, what effect does this have?
  • What should be done to ensure safety when using cables in the magnet environment?
  • How is spatial resolution affected when averages increase?
  • What distinguishes gradient echo imaging from spin echo imaging?
  • As TE increases, what happens to the signal to noise ratio?
  • Which type of magnet is most commonly used in MRI?
  • In Inversion Recovery, where does the first slice excitation pulse place LMz?
  • What is a common characteristic of tissues that have undergone high flip angles in MRI?
  • What does the chemical saturation technique do in MRI?
  • What is the benefit of using RF pulses spatially during MRI?
  • Susceptibility artifacts can be caused by?
  • How many TR periods occur in a spin echo pulse sequence if 200 phase encoding steps are selected?
  • Which method is considered effective for reducing echo spacing?
  • Who must screen anyone entering the magnet room?
  • Skin contact with the inside of the bore is unsafe because it:
  • What is defined as incorrect or misrepresented information in an MR image?
  • How does increasing TE affect spatial resolution?
  • What is a common cause of motion artifacts in MRI?
  • The term TE in MRI refers to what?
  • What happens to the number of protons that align in the parallel direction of the magnet as the magnetic field strength increases?
  • Motion artifacts occur in which direction?
  • CSF appears bright on a T2 weighted image due to its:
  • What happens to FID immediately after it is generated in a spin echo pulse sequence?
  • What is the name of the domain where phase encoding data is stored?
  • The precessional frequency difference between water and fat at 1.5 Tesla is approximately how many Hz?
  • What forms the basis of the echo train length in a fast/turbo spin echo sequence?
  • What gradient is used to generate an echo in a Gradient Echo (GRE) sequence?
  • Why is gadolinium considered an effective contrast agent for imaging?
  • Which of the following represents a diamagnetic material?
  • What is the expected outcome when MRI is used properly?
  • How is radio frequency transmission described in MRI terminology?
  • What is the most common MRI-related injury?
  • Which of the following is not considered a method to reduce artifacts in MRI?
  • What type of gradients indicate specific functions on a pulse sequence?
  • Which property makes certain metals paramagnetic?
  • What is the outcome on spatial resolution as frequency matrix increases?
  • What term describes signal dephasing due to local inhomogeneities in MRI?
  • Which statement is true about the relationship between scanning parameters and image quality?
  • Which term describes the combination of two factors in determining gradient efficiency?
  • Most injected MRI contrast agents are what type?
  • What does the enhancement seen after injecting a GBCA effectively represent?
  • Aliasing occurs when?
  • What is the non-toxic chemical that is bound to the Gd ion in GBCA's known as?
  • What happens to scan time if TR is increased in a spin echo pulse sequence?
  • Which of the following is NOT one of the four parts of an MRI pulse sequence?
  • A release of helium into the magnet room can lead to death by:
  • How does spatial resolution change with increased receive bandwidth?
  • In a FLAIR IR pulse sequence, which of the following is suppressed?
  • What does the term susceptibility in magnetism refer to?
  • What happens to scan time when the frequency matrix is increased?
  • Increasing the phase matrix in MRI will have what effect on image quality?
  • What is the term used for the measurement of a gradient's minimum to maximum field difference?
  • Burns caused by looped cables may show ______________ symptoms.
  • How does scan time change when averages increase?
  • Chemical shift artifacts do what as field strength increases?
  • What is the effect on signal intensity as TE increases?
  • What happens to SNR as receive bandwidth increases?
  • Which law describes the strong magnetic field produced by heavy electric current passing through a conductor?
  • What is the frequency called that is perfectly matched to the frequencies of a set of protons?
  • What distinguishes diamagnetic materials from others?
  • What is the theoretical point where all molecular motion stops, known as 0 Degree Kelvin?
  • Who should conduct the first screening of a patient before entering the magnetic field?
  • What is the term for the combination of the Gd ion and the ligand?
  • Which imaging approach typically uses less than 90-degree excitation pulses?
  • What are the three main functions of MRI gradients?
  • Corduroy artifacts most likely require what action?
  • What parameter is used in Inversion Recovery but not in Spin Echo?
  • Non-ferrous implants may be considered unsafe if they are:
  • When electrical current is run in the same direction as the main magnetic field, what happens to the gradients induced magnetic field?
  • When are hearing aids permitted to be worn into the magnet room?
  • True or False: Magnetic susceptibility effects can both degrade and improve diagnostic image quality.
  • What happens to spatial resolution when the phase matrix is increased?
  • Which property of materials does SAR essentially measure?
  • Which factor contributes to tissue saturation during MRI?
  • Which type of magnet in MRI provides the highest performance levels in image quality and speed?
  • What is the equivalent of 10,000 Gauss in Tesla?
  • What is the effect on SNR when slice thickness increases?
  • What is the purpose of the STIR sequence in MRI?
  • Which of the following materials would you associate with ferromagnetism?
  • What is the name of the time interval between the 180 and the first 90-degree RF pulse in Inversion Recovery?
  • What is the relationship between TR and signal recovery in a spin echo pulse sequence?
  • In a pulse sequence diagram, what does Gz refer to?
  • Which of the following describes vectors that are equal but opposite?
  • Truncation/Gibbs artifacts appear as what type of appearance?
  • What is the type of liquid used in MRI as a cryogen?
  • What is the primary purpose of gradients in MRI?
  • Which type of MRI pulse sequence typically requires phase encoding steps to be adjusted for optimal results?
  • What is referred to as the null point in MRI?
  • What term describes the explosive conversion of liquid helium to gaseous helium?
  • What happens to the force exerted on an object as it moves closer to the magnet?
  • Motion artifacts are caused by which of the following?
  • What should be ensured regarding patient equipment in an MRI environment?
  • True or False: Neurostimulators are an absolute contraindication for MRI.
  • True or False: The magnetic field strength of an MRI system can be determined by its size.
  • Which of the following can lead to increased susceptibility artifacts?
  • How can Truncation/Gibbs artifacts be reduced?
  • A characteristic of tissue at the null point is:
  • What are pre-saturation RF pulses used for?
  • What happens to scan time as Frequency Matrix increases?
  • What is the most effective way to decrease chemical shift artifacts?
  • What effect does an increase in frequency matrix have on SNR?
  • What type of pulses are used in GRE to eliminate residual transverse magnetization?
  • During the readout phase of a spin echo pulse sequence, which gradient is primarily used?
  • What occurs when there is residual transverse magnetization in a tissue?
  • What is the main effect of the gradient magnetic field on spins?
  • In a spin echo pulse sequence, what increases if the time from the 90 degree RF pulse is increased?
  • In k-space, which lines contain the majority of SNR information?
  • Which regulatory body oversees SAR guidelines in the United States?
  • A best practice for any cables in the magnet bore is to _______________.
  • What is the summation of all the magnetic moments of individual spins along the surface plane of the magnetic field called?
  • In the absence of a magnetic field, how are the orientations of spins characterized?
  • What is the term for the process when liquid helium explosively turns into gas?
  • What is the primary purpose of gradients in MRI?
  • What is the result when all spins in an MRI system are pointing in the Z direction?
  • What occurs if the TR is very short in a spin echo pulse sequence?
  • Why does fat appear bright on a T1 weighted image?
  • What characterizes a single shot or snapshot fast/turbo spin echo sequence?
  • At a minimum, how many times should a patient be screened before entering the magnetic field?
  • At what temperature does helium liquefy?
  • When is the phase encoding gradient activated in a spin echo pulse sequence?
  • What term is used for vectors that cancel each other?
  • What does TR stand for in MRI terminology?
  • Which type of patient is at a higher risk of radio frequency burns?
  • Which magnet type used in MRI can be routinely turned on and off?
  • How does scan time change as the FOV increases?
  • How do gadolinium based contrast agents increase imaging effectiveness?
  • What effect is observed in SNR when the field of view (FOV) is increased?
  • What type of material is known as paramagnetic?
  • What type of impact can occur due to electrical conductor arcing?
  • What does the physical gradient that encodes in the inferior-superior direction represent?
  • What can be concluded when the phase matrix is increased?
  • What characteristic of metals often indicates ferromagnetism?
  • Which parameter is affected by increasing the TE in a spin echo pulse sequence?
  • According to Faraday's Law, what effect does a magnetic field moving across a conductor have?
  • What happens to scan time as TR increases?
  • Which of the following is an example of a ferromagnetic material?
  • Good methods for reducing respiratory ghosting artifacts include?
  • What type of imaging is affected by banding artifacts in MRI?
  • What is the potential impact of software bugs in MR imaging?
  • How common are MRI related injuries?
Subscribe

Get the latest from Passetra